Mikasa Industry

Monday, November 20, 2017
 JAPANESE |  ENGLISH

Technical Information/Reference

Sorry, this entry is only available in 日本語.

(日本語) Mikasa会社案内パンフレット

Posted by admin On April - 18 - 2012 ADD COMMENTS

Sorry, this entry is only available in 日本語.

Technical brochure was completed.

Posted by admin On May - 13 - 2011 ADD COMMENTS

1) Technical detail of Mikasa’s water lubricated bearing.
2) Suitable bearing for vertical pump.
3) If you are interested in environmental friendly bearing, please download.
4) If you are interested in dry-start of water lubricated bearing, please download.

Rubber Roll

Posted by admin On March - 23 - 2010 ADD COMMENTS

FEATURES

In order to meet severer condition onto rubber rollers, staffs of our technical department devote themselves constantly to develop peculiar rubber compound for covering severer line condition of the customers. [...]

CAUTION

1. The shaft must never be operated without water.

2. The clearance shown in the above list is to be considered for the application at normal temperature of water. When the water temperature reads more than 30°C, it is recommendable to have a little bigger clearance.

3. When inserting the shaft into our rubber bearings, any grease or oil must not be used. Soapy water is recommendable for the purpose.

4. Our rubber bearings should not be left near any heat, especially in direct sunshine for a long period of time. [...]

Reference document of the FF bearings for pumps

Posted by admin On March - 23 - 2010 ADD COMMENTS

Precautions at design

●Allowable PV value
ince allowable contact pressure is set as 6 (kgf/cm2) and allowable peripheral speed is set as 12 (m/sec), the allowable PV value becomes 6 × 12 = 72 (kgf/cm2・m/sec).

●Water supply amount
Supply an amount of 2 × bearing inside diameter (cm) = Q (l/min).

●Tolerance of the bearing outside diameter
It is based on clearance fit, in principle. [...]

Precautions at handling/usage

●Precautions at handling

1. Avoid direct sunlight.

2. Avoid adherence of oil and/or organic solvent.

3. Do not place in a location with a high temperature.

4. Do not put a heavy load on top. [...]